Furanic Compound Analysis and its relation to paper Insulation Ageing

Most transformers rely upon a combination of insulating oil and paper to provide insulation both between phases and phase and earth. Transformers are probably the most reliable components on the high voltage networks, having few moving parts. However, they are subject to long term ageing and degradation. Thermal degradation of the insulation occurs during life. … Read more

Introducing the Next Generation Asset Methodology

It’s here! The much anticipated next generation of the electricity distribution ‘Common Network Asset Indices Methodology’ also known by the catchy acronym CNAIM. Developed for the assessment, forecasting and regulatory reporting of asset risk in Great Britain, this methodology is based on more than 20 years of development and experience. This new version replaces its 2016 predecessor, for … Read more

Blog | VisNet® Hub: Frequently Asked Questions

In this article, we answer the most common questions about VisNet® Hub: the real-time monitoring device that operates in low voltage distribution substations to provide insight into substation efficiency and optimisation. How complicated is the VisNet® Hub to install? Providing you can answer these simple questions, installation is easy: Where will the VisNet be mounted? Where … Read more

Blog | 7 problems VisNet® Hub can help solve

VisNet® Hub is a radical approach to providing low voltage (LV) network visibility, providing valuable insight into the efficiency and optimisation of LV networks. If you’re wondering how this exciting new tech can deliver strategic and tactical return on investment, here are seven problems VisNet® Hub can help solve… 1. The LV network needs to … Read more

Blog | 3 options for LV monitoring

Countless specifications and strategies are being explored and adopted by electricity companies world wide based on the outcomes of trials and tests of low voltage (LV) network monitoring. It’s no small challenge: most electricity companies have significant numbers of secondary substations, and of these tens of thousands of substations, most have been installed in the … Read more

Acidic Oil Causes Problems…The How, the Why and the Action.

The next assessment which forms part of the basic oil quality assessment on any insulating medium (along with Moisture & BDV) is the acidity content of the oil.  The acidity content of a mineral oil should be determined in accordance with the IEC 62021: Insulating liquids. Determination of acidity. Automatic potentiometric titration methodology. The standard covers multiple fluid mediums and fluids such … Read more

6 signs you need predictive maintenance E-book

6 signs you need predictive maintenance Predictive maintenance (PdM) – using equipment monitoring and data analysis tools and techniques to spot problems in processes and defects in equipment to predict when remedial work will be needed – isn’t a new concept. It’s all about minimising the risk of asset failure. If you’re thinking about the … Read more

How Wet is the Oil…or is that How Wet is the Transformer?

Our next blog takes us onto moisture content, which forms part of the basic oil quality assessment (along with acidity & BDV) on any insulating medium such as mineral oil.  The moisture content of an oil should be determined in accordance with the IEC 60814: Insulating liquids. Oil-impregnated paper and pressboard. Determination of water by automatic coulometric Karl Fischer titration methodology by use … Read more